BTA12-800CWRG

STMicroelectronics · Snubberless™ Series

STMicroelectronics Snubberless™ series, BTA12-800CWRG, Alternistor TRIAC, Single, 800 V off-state, 12 A RMS on-state, 35 mA Igt, TO-220AB Insulated, -40°C to 125°C.

STMicroelectronics BTA12-800CWRG
Download datasheet (PDF)
[IN STOCK] In Stock: 427 pcs
$0.57/ pc

Volume pricing

Buy Now

MOQ 1 · Tube · RoHS · EIA-481 · DAP/DDP · T/T

Technical specifications

BTA12-800CWRG specifications
Parameter / AttributeSpecification / Value
SeriesSnubberless™
Triac typeAlternistor - Snubberless
MountingThrough Hole
Voltage - off state800 V
Voltage - gate trigger (Vgt)1.3 V
Current - hold (Ih)35 mA
Current - gate trigger (Igt)35 mA
Current - on state (It (RMS))12 A
Current - non rep. surge 50, 60Hz120A, 126A
Operating temperature-40°C~125°C(TJ)
PackageTube
ConfigurationSingle
CaseTO-220-3

Technical details

Alternistor Snubberless — no RC snubber needed for inductive loads

The ST BTA12-800CWRG is an Alternistor-Snubberless TRIAC rated for 800 V off-state voltage and 12 A RMS on-state current. The Snubberless™ construction means it commutates inductive loads — motors, solenoids, transformers — without the external RC snubber that standard triacs need, saving two components and a chunk of board area. It lives in a TO-220AB insulated package (the tab is electrically isolated, so you can bolt it to a shared heatsink without an insulating pad).

800 V off-state and 12 A RMS — sizing the load and the heatsink

The 800 V Vdrm gives you headroom on a 240 VAC line (peak ~340 V) or even a 480 VAC line-to-line (peak ~680 V) with margin. The 12 A RMS continuous rating sets the load power: at 240 VAC that is roughly 2880 W resistive, but inductive loads need derating for power factor and inrush. Gate trigger current is 35 mA max, gate trigger voltage 1.3 V max — a standard logic-level optocoupler or a small-signal transistor can drive it directly. Holding current is also 35 mA max, so it stays latched once triggered unless the load current drops below that threshold. Non-repetitive surge current is 120 A at 50 Hz, 126 A at 60 Hz — that is the peak the die can survive for one half-cycle. Useful for capacitive loads or motor start where the inrush can be 10× the steady-state current.

Active production, ROHS3, through-hole package

The tab is electrically isolated, which simplifies heatsinking in a metal enclosure — no mica washer needed, just thermal compound.