Skip to main content
6SL32303YE480UB0

6SL32303YE480UB0 Motor Driver Boards, Modules | siemens

MPN6SL32303YE480UB0Compare · similar
Active · In production

6SL32303YE480UB0 (siemens) Motor Driver Boards, Modules. Type Module; Series SINAMICS; Package Box. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $10,579.21000
StockOut of Stock

Specifications

6SL32303YE480UB0 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
SeriesSINAMICS
PackageBox
Load power132000 W
Load voltage400 to 480 V
Supply voltage380 to 480VAC
For Use With/Related ProductsG120X Series
6SL32303YE480UB0 Technical Specifications - Column 2
ParameterValue
TypeModule
StatusActive
MountingChassis Mount
Motor TypeAC Motor
Output current338 A
Operating temperature20°C to 45°C

Product details

Siemens SINAMICS G120X IP20 132 kW Motor Drive Module

Cabinet Placement and System Integration

The 6SL32303YE480UB0 is a chassis-mount inverter rated for 380–480 V AC three-phase input and 338 A output, suiting it for motor control in water treatment, HVAC, and heavy industrial fan or pump applications requiring enclosure-rated installation. The module ships as an open chassis (IP20) and depends on a parent enclosure for environmental protection; panel builders specify NEMA 1 or better when required by site conditions.

Engineering Verification Checklist

  • Confirm three-phase supply voltage at terminals U1/V1/W1 is within 380–480 V AC 50/60 Hz before applying line power
  • Verify output current rating of 338 A against motor nameplate full-load amperage and any derating for elevated ambient temperature
  • Inspect chassis-mount alignment and torque specifications for mounting hardware (typically M8 bolts per Siemens frame-size requirements)
  • Confirm motor leads land on output terminals U2/V2/W2 with correct phase rotation; incorrect rotation damages loads
  • Verify control wiring against G120X safety function requirements if installed in a safety-related system (SIL or PL rating per IEC 62061 / ISO 13849)
  • Record firmware version via the BOP-2 or SINAMICS Startdrive interface and retain in as-built documentation
  • Confirm protective bonding conductor cross-section matches local electrical code for fault currents consistent with 132 kW drive rating
  • Validate that operating temperature band (20°C–45°C) is not exceeded at the intended installation location; add enclosure ventilation or cooling if necessary
  • Perform no-load voltage and frequency checks before connecting motor, following Siemens commissioning manual procedure steps for initial parameterization

Alternate Selection Guidance

The following alternatives share identical electrical ratings (338 A output, 380–480 V AC, 132 kW) and belong to the same SINAMICS G120X series. They differ only in suffix designation, which controls options such as integrated filter type (UF versus C2) or communication variant. The suffix codes for 6SL32303YE48x variants are:

  • UB0 / UP0 / UF0 — FSF (Frame Size F) with basic operator panel; UP0 adds PROFIdrive, UF0 indicates filter variant per suffix digit
  • AB0 / AP0 / AF0 — FSF C2 variant (category C2 EMC compliance); same rating but different EMC filter configuration
  • 1UB0 / 1UP0 / 1UF0 — Frame size F variant with extended specification suffix per Siemens ordering convention; check actual dimension sheet for mechanical compatibility

All alternatives are ROHS3 compliant and chassis-mount. The panel builder must select based on EMC compliance class required at the installation site and any onboard communication protocol needed for the control system.

MPNRatingFilter / EMC ClassNotes
6SL32303YE480UB0338 A, 380–480 VUF (FSF)Seed
6SL32303YE480UP0338 A, 380–480 VFSFPROFIdrive variant
6SL32303YE480UF0338 A, 380–480 VFSFFilter suffix
6SL32303YE480AB0338 A, 380–480 VFSF C2Category C2 EMC
6SL32303YE480AF0338 A, 380–480 VFSF C2C2 filter variant
6SL32303YE480AP0338 A, 380–480 VFSF C2C2 + PROFIdrive
6SL32303YE481UB0338 A, 380–480 VFSFExtended suffix
6SL32303YE481UF0338 A, 380–480 VFSFExtended suffix, filter
6SL32303YE481UP0338 A, 380–480 VFSFExtended suffix, PROFIdrive

Frequently asked questions

Catalog value for “RoHS” (6SL32303YE480UB0)?

**RoHS** is recorded as **ROHS3 Compliant** for 6SL32303YE480UB0. If your drawing disagrees, the datasheet wins.

Typical use cases for 6SL32303YE480UB0?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

What does this page list for “Type” on 6SL32303YE480UB0?

The storefront table shows **Type**: Module. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Stock and scheduling for 6SL32303YE480UB0?

For 6SL32303YE480UB0, treat dates as indicative until confirmed on order. Ships quickly when in stock; otherwise lead time follows distributor or factory lots.

Engineering support on 6SL32303YE480UB0?

Parameter review is grounded in what this page lists; anything beyond that goes through manufacturer FAE channels or your qualification plan.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 6SL32303YE480UB0

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant