Skip to main content
6SL32203YE241UF0

6SL32203YE241UF0 Motor Driver Boards, Modules | siemens

MPN6SL32203YE241UF0Compare · similar
Active · In production

6SL32203YE241UF0 (siemens) Motor Driver Boards, Modules. Type Module; Series SINAMICS; Package Box. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $1,360.72000
StockOut of Stock

Specifications

6SL32203YE241UF0 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
SeriesSINAMICS
PackageBox
Load power7500 W
Load voltage400 to 480 V
Supply voltage380 to 480VAC
For Use With/Related ProductsG120X Series
6SL32203YE241UF0 Technical Specifications - Column 2
ParameterValue
TypeModule
StatusActive
MountingChassis Mount
Motor TypeAC Motor
Output current24 A
Operating temperature20°C to 45°C

Product details

Siemens SINAMICS G120X Drive Module (7.5 kW, Chassis)

Specified Ratings and Physical Form

ParameterValue
Output Current24 A
Motor TypeAC Motor
Input Voltage Range380–480 V AC
Power Rating7.5 kW
MountingChassis Mount
Encapsulation / PackageBox
Operating Temperature20°C ~ 45°C
SeriesSINAMICS G120X
Product StatusActive
RoHSROHS3 Compliant
For Use WithG120X Series (PM240-2 Power Module)

G120X Configurator Positioning

The G120X series targets pump, fan, and compressor applications in industrial environments. The FSB frame designation refers to a specific power/current class within the SINAMICS range, matched here to 24 A output. Modules are chassis-mountable for cabinet integration. Selection requires confirming drive-duty cycle, enclosure thermal management, and communication interface (PROFINET/PUS.

Parametric Comparison Against Alternates

All listed alternates share the same voltage range (380–480 V AC), output current (24 A), power rating (7.5 kW), and chassis-mount form factor. Differences appear only in the MPN suffix, which encodes the firmware variant, communications module, or regional certification code within Siemens' G120X configurator system.

SpecThis (UF0)UB0UP0AF0AB0AP0UF0 (240)UP0 (240)UB0 (240)
Current Output24 A24 A24 A24 A24 A24 A24 A24 A24 A
Voltage380–480 V380–480 V380–480 V380–480 V380–480 V380–480 V380–480 V380–480 V380–480 V
Power7.5 kW7.5 kW7.5 kW7.5 kW7.5 kW7.5 kW7.5 kW7.5 kW7.5 kW
MountingChassisChassisChassisChassisChassisChassisChassisChassisChassis
Similarity1.01.01.01.01.01.01.01.0

All alternates are mechanically and electrically equivalent to the seed. The suffix variation (UF0, UB0, UP0, AF0, AB0, AP0, UF0/UP0/UB0 on 240 variant) reflects firmware or interface differences that must be confirmed against the target machine configuration before ordering.

Engineering Verification Checklist

  • Confirm that the target motor nameplate current and voltage match the 380–480 V AC / 24 A rating of this module.
  • Verify thermal dissipation planning; the 20°C–45°C operating range requires cabinet airflow or derating for ambient above 40°C.
  • Confirm chassis mounting dimensions and mounting orientation match the panel cutout.
  • Validate that the selected MPN suffix (UF0) corresponds to the correct firmware version required by the PLC configuration.
  • Review emergency stop and safety function wiring against the intended machine safety category.
  • Confirm that the power module is paired with a compatible Control Unit and that the SINAMICS G120X firmware release matches the STARTER or Startdrive project.
  • Check that the supply impedance at the installation point does not exceed the module's short-circuit current rating.
  • Verify that motor cable length and shielding meet the EMC installation requirements for the G120X series.
  • Confirm ROHS3 compliance requirement is satisfied for the target market/equipment.

Frequently asked questions

Are there catalog alternates or second-source candidates for 6SL32203YE241UF0?

We screen on package, interface, headline electricals, and lifecycle cues visible here—not on marketing series names alone, and not as manufacturer interchange approval. Send target rails, loads, and clearance rules for a quote-backed short list.

What does this page list for “Operating temperature” on 6SL32203YE241UF0?

The storefront table shows **Operating temperature**: 20°C to 45°C. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

MOQ rules for 6SL32203YE241UF0 (6SL32203YE241UF0)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Catalog value for “Supply voltage” (6SL32203YE241UF0)?

**Supply voltage** is recorded as **380 to 480VAC** for 6SL32203YE241UF0. If your drawing disagrees, the datasheet wins.

Typical use cases for 6SL32203YE241UF0?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 6SL32203YE241UF0

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant