Skip to main content
6SL32302YH261AB0

6SL32302YH261AB0 Motor Driver Boards, Modules | siemens

MPN6SL32302YH261AB0Compare · similar
Active · In production

6SL32302YH261AB0 (siemens) Motor Driver Boards, Modules. Type Module; Series SINAMICS; Package Box. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $2,367.28000
StockOut of Stock

Specifications

6SL32302YH261AB0 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
SeriesSINAMICS
PackageBox
Load power11000 W
Load voltage600 to 690 V
Supply voltage500 to 690VAC
For Use With/Related ProductsG120X Series
6SL32302YH261AB0 Technical Specifications - Column 2
ParameterValue
TypeModule
StatusActive
MountingChassis Mount
Motor TypeAC Motor
Output current19 A
Operating temperature20°C to 45°C

Product details

Siemens G120X 11 kW Drive Module (500–690 V)

Ratings — 6SL32302YH261AB0

ParameterValue
Input Voltage500–690 V AC (three-phase)
Rated Output Current19 A
Mechanical Power11 kW
Motor TypeAC Motor
MountingChassis Mount
EnclosureIP20, Box
Operating Temperature20°C ~ 45°C
SeriesSINAMICS G120X
CertificationROHS3 Compliant
Product StatusActive

The SINAMICS G120X platform targets HVAC and pump applications in the 500–690 V band, a range common in industrial mid-voltage installs. The chassis-mount form factor requires field assembly into an enclosure providing IP20 or better; Siemens quotes the operating window as 20–45 °C ambient.

Alternate Suffix Comparison

Reader must qualify all listed alternates independently; similarity scores reflect catalog-parameter proximity only, not functional equivalence.

MPNVoltagePowerCurrentMotor TypeTempSimilarity
6SL32302YH261AB0500–690 V11 kW19 AAC Motor20°C~45°C
6SL32302YH261AP0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH261AF0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH261UB0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH261UF0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH261UP0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH260AB0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH260AF0500–690 V11 kW19 AAC Motor20°C~45°C1.0
6SL32302YH260UB0500–690 V11 kW19 AAC Motor20°C~45°C1.0

All nine share identical electrical ratings: 500–690 V, 19 A, 11 kW, AC Motor, chassis mount, IP20 box, 20–45 °C.

Why similar: AB0, AP0, AF0 share the same 6SL32302YH261 base, differing only in final-suffix letter (P, F vs B); the 6SL32302YH260 variants carry the prior base number and may represent an earlier firmware release or market-specific variant. The "C" vs "U" split in the title (FSD C / FSD U) indicates a firmware/configuration family distinction common to SINAMICS ordering codes, not an electrical rating change.

Engineering Verification Checklist

  • Confirm supply voltage range is three-phase 500–690 V at the installation point
  • Verify load current does not exceed 19 A continuous at the target motor
  • Confirm ambient temperature will stay within 20–45 °C; derate if cabinet airflow is marginal
  • Verify chassis mounting dimensions and Din-rail or panel-cutout requirements from Siemens G120X documentation
  • Confirm enclosure provides IP20 or better per IEC 60529 for the installation environment
  • Verify firmware variant (C vs U family) matches the application profile and any required fieldbus or safety function
  • Confirm motor nameplate voltage and current are compatible with drive parameterization (V/f or sensorless vector)
  • Verify RoHS3 compliance requirement is met for the end market
  • Check that the drive is configured with appropriate motor data and protection settings before energization

Frequently asked questions

What can substitute for 6SL32302YH261AB0 if supply tightens?

We narrow candidates from footprint, voltage/current class, and approvals visible on this page. Any change still needs your datasheet review and hardware qualification—not a guaranteed substitute from storefront text.

Catalog value for “For Use With/Related Products” (6SL32302YH261AB0)?

**For Use With/Related Products** is recorded as **G120X Series** for 6SL32302YH261AB0. If your drawing disagrees, the datasheet wins.

Lead time / allocation notes for 6SL32302YH261AB0 (6SL32302YH261AB0)?

siemens line card data is a snapshot. Ships quickly when in stock; otherwise lead time follows distributor or factory lots. Lock dates on your PO or distributor confirmation.

What is the minimum order quantity (MOQ) for 6SL32302YH261AB0?

MOQ for 6SL32302YH261AB0: Evaluation quantities are usually workable—confirm on RFQ.. Pilot builds can often start smaller—state your target annual usage in the RFQ.

What does this page list for “Operating temperature” on 6SL32302YH261AB0?

The storefront table shows **Operating temperature**: 20°C to 45°C. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 6SL32302YH261AB0

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant