Siemens 6SL32302YH260UP0 SINAMICS G120X Drive Module
The 6SL32302YH260UP0 is a chassis-mount power module in the SINAMICS G120X family, rated for three-phase AC motors up to 11 kW at supply voltages from 500 V to 690 V. Output current is specified at 19 A, with an operating range of 20°C to 45 °C in a box-style enclosure.
G120X Series Input Range and Safety Suffix Comparison
The G120X series offers variants identified by alphanumeric suffixes in positions 12–13 of the MPN (e.g., UP0, UF0, UB0, AP0). All share the same core rating: 500–690 V input, 11 kW motor capacity, 19 A output, chassis mounting, and ROHS3 compliance. The suffix primary indicates safety function type—UP0 and UF0 variants carry a U-series (universal) safety suffix, while AP0, AB0, and AF0 variants use a C-series (C2/Category 2 STO) suffix.
| Spec | 6SL32302YH260UP0 (seed) | 6SL32302YH260UF0 | 6SL32302YH260AP0 | 6SL32302YH260AB0 | 6SL32302YH261UP0 |
|---|---|---|---|---|---|
| Output current | 19 A | 19 A | 19 A | 19 A | 19 A |
| Input voltage | 500–690 V | 500–690 V | 500–690 V | 500–690 V | 500–690 V |
| Motor rating | 11 kW | 11 kW | 11 kW | 11 kW | 11 kW |
| Safety suffix | UP0 | UF0 | AP0 | AB0 | UP0 |
| Series | SINAMICS | SINAMICS | SINAMICS | SINAMICS | SINAMICS |
| Mounting | Chassis | Chassis | Chassis | Chassis | Chassis |
| Operating temp | 20°C–45°C | 20°C–45°C | 20°C–45°C | 20°C–45°C | 20°C–45°C |
| Similarity (0–1) | — | 1.0 | 1.0 | 1.0 | 1.0 |
Reader qualification required: parametric similarity does not imply safety function interchangeability. The U-series and C-series suffixes represent distinct STO architectures—verify compliance with the target machine's safety integrity level before substitution.
Why similar (UP0 vs UF0): Both carry the U-series suffix and share identical electrical ratings, mounting, and series designation—the only difference is a single character in the MPN trailing position.
Why similar (UP0 vs AP0): Both are G120X 11 kW 500–690 V modules with 19 A output and chassis mounting; the AP0 variant substitutes a C-series (Category 2) safety suffix for the U-series suffix.
Engineering Verification Checklist
- Confirm supply voltage range (500–690 V three-phase) matches available mains or transformer tap
- Verify motor nameplate current and power (11 kW, 19 A nominal) falls within module rating derating curve at expected ambient
- Check enclosure IP rating and mounting dimensions for chassis installation space
- Confirm safety function suffix matches machine safety circuit requirements (U-series vs C-series)
- Validate operating temperature range (20°C–45°C) against worst-case cabinet ambient with ventilation
- Verify PROFINET or fieldbus interface type if communications configuration is required
- Confirm ROHS3 compliance requirement for end market
- Review line-side and motor-side protective co-ordination with upstream short-circuit device
- Test STO input wiring and safety relay logic before live motor run