Siemens G120X Variable Frequency Drive — 500–690 V / 5.5 kW
G120X Series Comparison (Seed: 6SL32201YH220UP0)
All units share 13 A output, chassis mounting, 20–45 °C operating range, and ROHS3 compliance. Confirm suitability with your motor nameplate and installation environment before procurement.
| Spec | 6SL32201YH220UP0 (seed) | 6SL32201YH220UB0 | 6SL32201YH220UF0 | 6SL32201YH221UB0 |
|---|---|---|---|---|
| Voltage | 500–690 V | 500–690 V | 500–690 V | 500–690 V |
| Power | 5.5 kW | 5.5 kW | 5.5 kW | 5.5 kW |
| Output Current | 13 A | 13 A | 13 A | 13 A |
| Mount | Chassis | Chassis | Chassis | Chassis |
| Series | SINAMICS | SINAMICS | SINAMICS | SINAMICS G120X |
| Similarity | — | 1.00 | 1.00 | 1.00 |
- 6SL32201YH220UB0 — same 14-digit prefix; trailing block differs; identical voltage/current/power specs.
- 6SL32201YH220UF0 — minor suffix variant within the same family; chassis mount, same power envelope.
- 6SL32201YH221UB0 — revision shift in the middle digit block; series label includes explicit G120X designation.
G120X Inverter Specifications (6SL32201YH220UP0)
| Parameter | Value |
|---|---|
| Input Voltage | 500–690 V AC (3-phase) |
| Rated Output Power | 5.5 kW |
| Output Current | 13 A |
| Motor Compatibility | AC motors |
| Mounting | Chassis mount |
| Enclosure | Box (IP20) |
| Series | SINAMICS |
| Operating Temperature | 20°C to 45°C |
| Product Status | Active |
| Rohs | ROHS3 Compliant |
| For Use With | G120X Series |
The 6SL32201YH220UP0 carries a 14-digit numeric block preceding the final letter suffix, consistent with Siemens G120X chassis-mount inverter ordering conventions. The 500–690 V range targets medium-voltage industrial motor applications where supply nominals exceed standard 380–480 V drives.
Engineering Verification Checklist
- Confirm motor rated voltage and current align with 5.5 kW / 13 A drive output.
- Verify supply system is 3-phase, 500–690 V nominal.
- Validate chassis mounting dimensions and cutout requirements.
- Check that enclosure IP20 rating suits the target environment (no wash-down or outdoor exposure).
- Confirm operating temperature window (20–45 °C) covers worst-case cabinet ambient.
- Review whether the drive suffix (UP0 vs. UB0/UF0/AB0) implies integration with a specific control unit (CU) or operator panel.
- Verify grounding and PE conductor sizing per IEC/EN standards for the 13 A output rating.
- Confirm EMC filtering and line Reactors are included or required separately for your installation class.
- Review start-up and parameterization tooling (SINAMICS Startdrive or similar) availability.