1500 W peak pulse, 22.5 V clamp — the rail protection spec
The 1.5SMC16AS_R1_00001: The 13.6 V reverse standoff is the DC bias the protected line normally sits at; the diode stays off below that, only starts conducting when the transient pushes past the 15.2 V minimum breakdown threshold. Single unidirectional channel — one TVS cell in the DO-214AB (SMC) body.
Active production, surface-mount BOM fit
Marked active in the lifecycle record — no NRND or EOL flag on this Panjit order code. The DO-214AB (SMC) footprint is a standard JEDEC outline; the reeled tape-and-reel packaging (Cut Tape also available) feeds into a standard pick-and-place line without a feeder change. General-purpose application classification — no power-line protection flag (the spec explicitly says Power Line Protection: No), so it is intended for signal or low-voltage DC rail clamping, not mains-side suppression.