1500W peak pulse – the surge rating that defines the protection window
Breakdown voltage starts at 37.1V minimum, clamping at 53.9V maximum at the peak pulse current, with a 33.3V reverse standoff. The standoff voltage is the DC rail the part sits across without conducting; the clamp voltage is where the TVS forces the surge current to ground. The gap between them — roughly 20V — is the protection window the load must survive.
onsemi lists the 1N6285ARL4 as Obsolete. The package is axial, through-hole, supplied on Tape & Reel. That package is common across the 1N6285 family, so a same-package sibling (e.g. 1N6285A) is a drop-in candidate if the electrical ratings match the application.
Through-hole axial mounting simplifies hand-rework and retrofit but occupies more board area than a surface-mount equivalent.