NXP Semiconductors MP3V5050VC6U — Discrete Semiconductors

NXP MP3V5050VC6U Vacuum Pressure Sensor, -7.25 PSI

MPNMP3V5050VC6U
End of Life

NXP MP3V5050VC6U, series MP3V5050, vacuum pressure sensor, -7.25 PSI operating pressure, analog voltage output 0.06 V to 2.82 V, ±2.5% accuracy, amplified output, temperature compensated, 8-SMD Gull Wing top port, surface mount, -40°C to 125°C, 2.7 V to 3.3 V supply.

$20.63Ref. price · indicative, final on quote
Packaging8-SMD, Gull Wing, Top Port
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MP3V5050VC6U Technical Specifications
ParameterValue
SeriesMP3V5050
Output typeAnalog Voltage
Mounting typeSurface Mount
Pressure typeVacuum
Voltage2.7V ~ 3.3V
Operating temperature-40°C ~ 125°C
Output0.06 V ~ 2.82 V
PackageTube
Accuracy±2.5%
FeaturesAmplified Output, Temperature Compensated
Port sizeMale - 0.13\" (3.17mm) Tube
Port styleBarbless
ApplicationsBoard Mount
Case8-SMD, Gull Wing, Top Port
Maximum pressure-29.01PSI (-200kPa)
Termination styleGull Wing
Operating pressure-7.25PSI (-50kPa)

Product details

Vacuum pressure sensor with amplified analog output

The NXP MP3V5050VC6U is a board-mount vacuum pressure sensor in the MP3V5050 series. It measures vacuum pressure down to -7.25 PSI (-50 kPa) and outputs a ratiometric analog voltage from 0.06 V at minimum pressure to 2.82 V at maximum. The output is amplified and temperature compensated, so you get a clean, predictable signal across the rated range without external conditioning. Supply it with 2.7 V to 3.3 V and read the voltage directly into an ADC.

Temperature range and accuracy

Rated for -40°C to 125°C operating temperature, this sensor handles industrial enclosures, outdoor telecom cabinets, and under-hood automotive environments. The ±2.5% accuracy is the total error band including offset, span, linearity, and temperature effects — no additional calibration needed for most applications. If your system needs tighter than 2.5% FS, plan for a two-point calibration at your operating pressure.

Lifecycle and sourcing

The MP3V5050VC6U is listed as Active with ROHS3 compliance. No end-of-life notice or last-time-buy window is in effect. This part is sourced through independent distribution and quoted to order against an RFQ.

Frequently asked questions

Is MP3V5050VC6U absolute, gauge, or vacuum pressure?

It is a vacuum pressure sensor. The operating pressure is -7.25 PSI (-50 kPa), referenced to atmospheric pressure. It measures negative gauge pressure (vacuum), not absolute or differential.

What is the accuracy of MP3V5050VC6U?

The accuracy is ±2.5% full scale over the rated temperature range. This includes offset, span, linearity, and temperature drift.

What package does MP3V5050VC6U come in?

The port is a male barbless tube for 0.13" (3.17 mm) ID tubing. Surface-mount assembly.