Skip to main content
NXP Semiconductors MP3V5050VC6U — Discrete Semiconductors

NXP MP3V5050VC6U Vacuum Pressure Sensor, -7.25 PSI

MPNMP3V5050VC6U
End of Life

NXP MP3V5050VC6U, series MP3V5050, vacuum pressure sensor, -7.25 PSI operating pressure, analog voltage output 0.06 V to 2.82 V, ±2.5% accuracy, amplified output, temperature compensated, 8-SMD Gull Wing top port, surface mount, -40°C to 125°C, 2.7 V to 3.3 V supply.

$20.63Ref. price · indicative, final on quote
Packaging8-SMD, Gull Wing, Top Port
RoHSROHS3 Compliant
SeriesMP3V5050
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MP3V5050VC6U specifications
ParameterValue
SeriesMP3V5050
Output typeAnalog Voltage
MountingSurface Mount
Pressure typeVacuum
Supply voltage2.7V ~ 3.3V
Operating temperature-40°C ~ 125°C
Output0.06 V ~ 2.82 V
PackageTube
Accuracy±2.5%
FeaturesAmplified Output, Temperature Compensated
Port sizeMale - 0.13\" (3.17mm) Tube
Port styleBarbless
ApplicationsBoard Mount
Case8-SMD, Gull Wing, Top Port
Maximum pressure-29.01PSI (-200kPa)
Termination styleGull Wing
Operating pressure-7.25PSI (-50kPa)

Product details

Vacuum pressure sensor with amplified analog output

The NXP MP3V5050VC6U is a board-mount vacuum pressure sensor in the MP3V5050 series. It measures vacuum pressure down to -7.25 PSI (-50 kPa) and outputs a ratiometric analog voltage from 0.06 V at minimum pressure to 2.82 V at maximum. The output is amplified and temperature compensated, so you get a clean, predictable signal across the rated range without external conditioning.

Temperature range and accuracy

The ±2.5% accuracy is the total error band including offset, span, linearity, and temperature effects — no additional calibration needed for most applications. If your system needs tighter than 2.5% FS, plan for a two-point calibration at your operating pressure.

Frequently asked questions

Is MP3V5050VC6U absolute, gauge, or vacuum pressure?

It is a vacuum pressure sensor. The operating pressure is -7.25 PSI (-50 kPa), referenced to atmospheric pressure. It measures negative gauge pressure (vacuum), not absolute or differential.

What is the accuracy of MP3V5050VC6U?

The accuracy is ±2.5% full scale over the rated temperature range. This includes offset, span, linearity, and temperature drift.

What package does MP3V5050VC6U come in?

The port is a male barbless tube for 0.13" (3.17 mm) ID tubing. Surface-mount assembly.