Clamping voltage and breakdown threshold
The minimum breakdown voltage is 64.4V, meaning the device starts conducting just above the normal operating level, and the maximum clamping voltage is 93.6V at the rated peak pulse current of 16A.
Peak pulse power and surge capability
The 16A peak pulse current at the clamping voltage confirms the device can absorb a heavy transient without failing short.
Housed in the DO-214AB (SMC) package, surface-mount, supplied on Tape & Reel. The DO-214AB footprint is common across many TVS families, making this a drop-in replacement candidate for existing 58V bidirectional designs.