Skip to main content
Microchip Technology SMCJ13E3/TR13 — Circuit Protection

SMCJ13E3/TR13 TVS Diode – 1500W, 13V Standoff, DO-214AB

MPNSMCJ13E3/TR13
Active

Microchip Technology SMCJ13E3/TR13, Zener TVS diode, 1500W peak pulse power, 13V reverse standoff, single unidirectional channel, DO-214AB (SMC) package, Tape & Reel.

$0.5550Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

SMCJ13E3/TR13 specifications
ParameterValue
TypeZener
MountingSurface Mount
Voltage - breakdown14.4V
Voltage - clamping (Max) @ ipp23.8V
Voltage - reverse standoff13V
Current - peak pulse (10/1000μs)63A
Power - peak pulse1500W (1.5kW)
Power line protectionNo
Operating temperature-65°C~150°C(TJ)
PackageTape & Reel (TR)
ApplicationsGeneral Purpose
CaseDO-214AB, SMC
Unidirectional channels1

Product details

Sizing the protection for a 13V rail

Its 1500W peak pulse power rating (10/1000µs waveform) means it can absorb a 63A surge before the clamping voltage hits 23.8V — enough margin for most 12V nominal supplies in industrial or telecom gear.

What the clamping and breakdown specs mean for your BOM

The minimum breakdown voltage is 14.4V, so the part starts conducting at that threshold. The clamping voltage at peak current is 23.8V — the downstream circuitry must survive that level during a surge event. This is a single unidirectional channel; for bidirectional protection on an AC line or a signal pair, you would need two parts back-to-back or a different TVS family.

For volume pricing and lead time, submit an RFQ against your target quantity. The DO-214AB (SMC) footprint is widely second-sourced, so qualifying an alternate is straightforward if allocation ever tightens.

Frequently asked questions

What is the closest pin-compatible alternative to SMCJ13E3/TR13?

The SMCJ13A is a direct functional alternative in the same DO-214AB package and 1500W family. The 'A' suffix denotes a 5% breakdown tolerance versus the standard 10% on the suffix. Confirm the breakdown voltage tolerance your design requires before substituting.