500 W peak pulse power in a DO-214AC body
The clamping voltage at peak pulse current is 146 V max, which sets the voltage the downstream circuitry must survive during a surge event. Breakdown voltage min is 100 V, so the part starts conducting at that threshold and clamps the transient before it reaches the 146 V ceiling. The 3.4 A peak pulse current rating is the current the diode can sink during the 10/1000 µs pulse without failing.
Package and temperature range for board integration
Housed in a DO-214AC (SMA) package, the same footprint as many standard TVS diodes, so PCB layout reuse is straightforward.