70V rail clamp in a rework-friendly SMA package
It handles a 500W peak pulse (10/1000µs waveform) and clamps at 125V max at 4A.
Clamping voltage and peak pulse power
The clamping voltage of 125V at 4A peak pulse current (10/1000µs) defines the protection ceiling — downstream components must survive that voltage for the pulse duration. The 500W peak pulse power rating is the energy-handling envelope for a single surge event.
Microchip lists the SMAJ70CE3/TR13 as Active.
Bidirectional — one device for both polarities
The DO-214AC (SMA) body is symmetrical — no orientation worry during pick-and-place.