43V rail protection – breakdown and clamp voltages
Its reverse standoff voltage is 43V, meaning the device does not conduct appreciably below that level. The minimum breakdown voltage is 47.8V, guaranteeing the avalanche starts before the rail sees a transient above that threshold.
500W peak pulse – surge capability in DO-214AC