500W Zener TVS for 11V Rails
Breakdown and Clamping Margins
Minimum breakdown voltage is 12.2V, ensuring the part does not conduct at the 11V standoff level. Maximum clamping voltage at peak pulse current (24.9A) is 20.1V — this is the voltage the protected circuitry must survive during a surge.
Active Production, DO-214AC Package
Package is DO-214AC (SMA), a surface-mount footprint common for TVS diodes in this power class. The part is supplied on reel for volume production.