Skip to main content
Microchip Technology MIC2043-1YM — Discrete Semiconductors

MIC2043-1YM High-Side Power Switch, 3A, 8-SOIC, Active

MPNMIC2043-1YM
End of Life

Microchip Technology MIC2043-1YM high-side power switch, single N-channel output, 3A max, 40 mOhm Rds(on), 1.6V-5.5V load, 8-SOIC tube.

$2.88Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
RoHSROHS3 Compliant
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MIC2043-1YM specifications
ParameterValue
Input typeNon-Inverting
Output typeN-Channel
TypeGeneral Purpose
MountingSurface Mount
Voltage - load1.6V ~ 5.5V
Voltage - supply (Vcc (Vdd))1.6V ~ 5.5V
Output current3A
I/O channels1
InterfaceOn/Off
Operating temperature-40°C ~ 85°C (TA)
PackageTube
FeaturesSlew Rate Controlled, Status Flag
Rds on40mOhm
Case8-SOIC (0.154\", 3.90mm Width)
Fault protectionCurrent Limiting (Adjustable), Open Load Detect, Over Temperature, UVLO
Output configurationHigh Side
Ratio - Input:Output1:1

Product details

Key ratings and what they mean for the board

The MIC2043-1YM: Rated for a continuous output current of 3 A max, with a typical on-resistance of 40 mOhm. At 3 A the conduction loss is I²R = 0.36 W — the 8-SOIC copper pad area under the die sets the thermal budget; a 1 oz pour on the PCB keeps the junction below the 85 °C ambient limit. The supply (Vcc/Vdd) range is the same, so the same rail can drive the gate drive and the load. Fault protection includes adjustable current limiting, open-load detection, over-temperature shutdown, and under-voltage lockout (UVLO). The Status Flag output signals a fault condition to the host controller — useful for hot-swap or USB port power management where the system needs to know when a port is overloaded.

ROHS3 compliant — no restricted substances per the latest EU directive.

Frequently asked questions

What fault protection does the MIC2043-1YM include?

It includes adjustable current limiting, open-load detection, over-temperature shutdown, and under-voltage lockout (UVLO). A Status Flag output signals a fault condition to the host controller.

What is the maximum output current and on-resistance?

The maximum continuous output current is 3 A, with a typical on-resistance of 40 mOhm. At 3 A the conduction loss is about 0.36 W.