The DSC6112CI1A-000.0000T: The AEC-Q100 rating means it passed automotive-grade reliability stress — temperature cycling, ESD, and latch-up screening — so it was designed for under-hood or chassis-mounted electronics where thermal and vibration margins are tight.
Supply rail and standby draw
Active current draw is 3 mA typical at max frequency; in standby mode (pin-controlled) the disable current drops to 12 µA, so a battery-backed RTC or wake-up timer can leave the oscillator powered without draining the coin cell.
4-SMD no-lead footprint