Obsolete — last-time-buy sourcing through independent channels
The DSC6111HE2A-PROGRAMMABLE: Sourcing this part now goes through independent surplus and broker channels.
3 mA typ active current, 12 µA standby — power budget fit
Active current draw is 3 mA typical — this is the full-rail consumption at maximum frequency within the 1 MHz to 100 MHz range, not a no-load figure. Standby mode pulls 12 µA maximum via the Standby function pin, keeping the clock tree alive for wake-on-event without draining the battery in a key-off automotive module.
For a CAN bus or FlexRay reference clock, ±25 ppm keeps the bit timing within the 1% tolerance window — a wider stability would risk synchronization faults on the bus.