AEC-Q100 qualification for under-hood clocking
Rated AEC-Q100, the DSC1001CL5-010.0000T carries the automotive-grade qualification required for engine-bay ECUs and ADAS sensor modules that see -40°C to 105°C ambient.
Supply voltage and output compatibility
The CMOS output drives standard logic inputs directly without a level translator.
Frequency stability and standby power
±10 ppm frequency stability holds the 10 MHz reference within 100 ps of jitter budget for CAN-FD and 100BASE-T1 timing.
4-SMD no-lead package, 3.20 mm x 2.50 mm, 0.90 mm seated height.