Skip to main content
Littelfuse Inc. 1206L350SLWR — Circuit Protection

Littelfuse 1206L350SLWR PTC Resettable Fuse, 3.5 A Hold

MPN1206L350SLWR
Active

Littelfuse Inc. POLY-FUSE®, LoRho series, Type Polymeric, 1206L350SLWR PTC resettable fuse, 3.5 A hold current, 50 A max current, 6 V max voltage, 1206 SMD package.

$2.1900Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1206L350SLWR specifications
ParameterValue
TypePolymeric
SeriesPOLY-FUSE®, LoRho
MountingSurface Mount
Voltage - max6V
Current - max50 A
Current - trip7 A
Current - hold (Ih)3.5 A
Operating temperature-40°C ~ 85°C
Size (Dimension)0.128\" L x 0.065\" W (3.25mm x 1.65mm)
Approval agencycURus, TUV
PackageTape & Reel (TR) Cut Tape (CT)
Time to trip2 s
Case1206 (3216 Metric), Concave
Thickness0.030\" (0.75mm)
Resistance - initial (Ri)3 mOhms
Resistance - post trip (R1)18 mOhms

Product details

Active production — 3.5 A hold in a 1206 footprint

The 1206L350SLWR is an active-production polymeric PTC from the POLY-FUSE LoRho series, rated for 3.5 A hold current (Ih) at 6 V max with a 50 A interrupt rating. Its 3 mOhm typical initial resistance keeps I²R losses low in the 3.5 A pass-through state — the post-trip resistance climbs to 18 mOhm max after the polymer switches, limiting fault current to a safe level.

Trip behaviour and thermal budget

At fault current the device trips in 2 seconds typical — fast enough to protect downstream components in a 6 V rail without nuisance opening on inrush. The 1206 concave package (3.25 mm × 1.65 mm, 0.75 mm thick) keeps the board footprint small, but the 3.5 A hold current means the trace width feeding it should be sized for continuous current plus the thermal rise from the PTC's own resistance.

Approvals and compliance

Carries cURus and TUV approvals, covering North American and European equipment safety requirements for a polymeric PTC in a 6 V circuit.

Frequently asked questions

What is the 1206L350SLWR's hold current and trip current?

Hold current (Ih) is 3.5 A maximum at 25°C; trip current (It) is 7 A. At fault current above 7 A the device trips in 2 seconds typical, resetting when power is removed and the polymer cools.