Skip to main content
Littelfuse Inc. 1206L260SLTHYR — Circuit Protection

Littelfuse 1206L260SLTHYR PTC Resettable Fuse, 2.6A Hold, 6V

MPN1206L260SLTHYR
Active

Littelfuse Inc. POLY-FUSE®, LoRho series polymeric PTC resettable fuse, 1206L260SLTHYR, 2.6 A hold, 6 V max, 50 A max interrupt, 1206 (3216 Metric) concave surface mount.

$1.8500Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1206L260SLTHYR specifications
ParameterValue
TypePolymeric
SeriesPOLY-FUSE®, LoRho
MountingSurface Mount
Voltage - max6V
Current - max50 A
Current - trip5 A
Current - hold (Ih)2.6 A
Operating temperature-40°C~85°C
Size (Dimension)0.128\" L x 0.065\" W (3.25mm x 1.65mm)
Approval agencycURus, TUV
PackageTape & Reel (TR); Cut Tape (CT)
Time to trip4 s
Case1206 (3216 Metric), Concave
Thickness0.028\" (0.70mm)
Resistance - initial (Ri)3 mOhms
Resistance - post trip (R1)26 mOhms

Product details

Polymeric PTC for low-resistance bus protection

The 1206L260SLTHYR is a Littelfuse POLY-FUSE LoRho series polymeric PTC resettable fuse. It holds 2.6 A continuously and trips at 5 A, protecting a 6 V rail from overcurrent faults up to 50 A.

2.6 A hold, 3 mOhm initial resistance

Initial resistance is 3 mOhms minimum, rising to 26 mOhms max after trip. The low Rmin keeps I²R losses under 20 mW at rated hold current, which matters for battery-powered or high-density boards where every milliwatt of self-heating eats into the thermal budget. The 1206 concave package (3.25 mm x 1.65 mm, 0.70 mm thick) is a standard footprint for automated pick-and-place. Surface-mount reflow profile follows the solder paste manufacturer's recommendation for the 3216 metric body. The trip time is 4 seconds at 8 A (roughly 3x Ihold), which is fast enough to protect downstream components from sustained shorts but slow enough to ignore inrush from a 100 µF bypass cap bank.

Active production, cURus and TUV approved

Safety agency approvals include cURus and TUV, covering North American and European equipment standards. No RoHS or REACH statement is in the spec record, but the POLY-FUSE series is typically RoHS-compliant — confirm with the manufacturer for your compliance file.

Frequently asked questions

What is the hold current and trip current of the 1206L260SLTHYR?

Hold current (Ihold) is 2.6 A maximum; trip current (Itrip) is 5 A. The device will not trip below 2.6 A continuous and is guaranteed to trip at 5 A within 4 seconds at 25°C.

What package does the 1206L260SLTHYR come in?

It is a 1206 (3216 Metric) concave surface-mount package, 3.25 mm long by 1.65 mm wide, 0.70 mm thick. Supplied in tape-and-reel or cut-tape options.