1206L035YR Littelfuse PTC Resettable Fuse, 350 mA, 6V, 1206

MPN1206L035YR
Active

Littelfuse Inc. POLY-FUSE® 1206L series PTC resettable fuse, 1206L035YR, 350 mA hold, 750 mA trip, 6V max, 100 ms trip time, surface mount 1206 (3216 Metric) concave package, Tape & Reel.

$0.4900Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1206L035YR specifications
ParameterValue
TypePolymeric
SeriesPOLY-FUSE®, 1206L
MountingSurface Mount
Voltage - max6V
Current - max100 A
Current - trip750 mA
Current - hold (Ih)350 mA
Operating temperature-40°C ~ 85°C
Size (Dimension)0.126\" L x 0.065\" W (3.20mm x 1.65mm)
Approval agencycURus, TUV
PackageTape & Reel (TR) Cut Tape (CT)
Time to trip100 ms
Case1206 (3216 Metric), Concave
Thickness0.030\" (0.75mm)
Resistance - initial (Ri)300 mOhms
Resistance - post trip (R1)1.2 Ohms

Product details

350 mA hold, 6V max — POLY-FUSE 1206L PTC resettable fuse

The Littelfuse 1206L035YR is a polymeric PTC resettable fuse from the POLY-FUSE 1206L series, rated for 350 mA hold current (Ih) with a 750 mA trip current (It) and a maximum voltage of 6V. It resets after a fault clears — no fuse replacement needed on the board, which saves a service call on a sealed assembly. The 1206 (3216 Metric) concave package sits at 0.030" (0.75 mm) thick, surface-mount, and the 100 ms typical trip time at 100 A max fault current means it clears fast enough to protect downstream traces and connectors in a low-voltage rail.

Active production — no obsolescence watch needed

The approvals — cURus and TUV — cover North American and European safety agency acceptance, so the same reel clears both UL and IEC-based equipment certifications without a component change.

Sourcing and compliance

Operating temperature range is -40°C to 85°C, covering most indoor and outdoor equipment enclosures. Initial resistance (Ri) is 300 mOhms minimum, rising to 1.2 Ohms max after a trip event — the post-trip resistance is the figure to budget for voltage drop in the faulted state.

Frequently asked questions

Where can I buy 1206L035YR and how do I get a price?

The 1206L035YR is sourced to order against the BOM through independent distribution.

What is 1206L035YR's hold current and trip current?

The hold current (Ih) is 350 mA maximum; the trip current (It) is 750 mA. At 100 A max fault current, the typical trip time is 100 ms, clearing the fault before downstream components exceed their ratings.