Voltage ratings and clamping behaviour
The 1.5SMC250CA: That 107V window between standoff and clamp gives the designer headroom for transient energy absorption without exceeding the protected device's absolute maximum rating. The bidirectional configuration (single channel) means a single device clamps both positive and negative transients, simplifying board layout for AC-coupled or floating lines.