Skip to main content
Littelfuse Inc. 0467.750NRHF — Circuit Protection

0467.750NRHF Littelfuse 467 Series

MPN0467.750NRHF
Active

Littelfuse Inc. Series 467 Board Mount (Cartridge Style Excluded), 0467.750NRHF, 750 mA, 32 V AC/DC, Fast Blow, 0603 (1608 Metric), 50 A breaking capacity.

$1.3700Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

0467.750NRHF specifications
ParameterValue
Series467
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - AC32 V
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating750 mA
Response timeFast Blow
Operating temperature-55°C ~ 90°C
Size (Dimension)0.063\" L x 0.032\" W x 0.012\" H (1.60mm x 0.81mm x 0.31mm)
Approval agencyCSA, UL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t0.0171
Case0603 (1608 Metric)
DC cold resistance0.117 Ohms

Product details

750 mA fast-blow protection in a 0603 SMT footprint

The Littelfuse 0467.750NRHF is a Series 467 surface-mount fuse rated 750 mA with a fast-blow response time, designed for overcurrent protection on dense PCBs where space is tight. Rated 32 V AC and 32 V DC, it handles common low-voltage rail protection — think 24 VDC control circuits, sensor power feeds, or battery management lines. Breaking capacity is 50 A at rated voltage, meaning it can safely interrupt a fault current up to that level without rupturing — a solid margin for most secondary-side protection zones.

Selection and coordination parameters

Melting I²t is 0.0171 — this number is what you feed into the coordination study with the upstream breaker or PTC to ensure the fuse opens before the next device up the chain. Operating temperature spans -55°C to 90°C, so it holds calibration in outdoor telecom cabinets or unheated factory floors without derating concerns.

Frequently asked questions

What is the breaking capacity of 0467.750NRHF?

50 A at the rated voltage of 32 V AC or DC. This means the fuse can safely interrupt a short-circuit current up to 50 A without damaging the board.

What approvals does 0467.750NRHF carry?

CSA and UL — both recognized safety agency marks for North American equipment certification.