Temperature range and derating
The TPSY227M010R0100: Standard practice with tantalum electrolytics is to derate the applied voltage by 20% — for a 10 V rated part, keep the steady-state rail below 8 V to avoid surge failures.
2917 footprint and PCB layout fit
The Y-size code corresponds to the 2917 body. Solder profile follows standard tantalum reflow — peak temperature 260°C, ramp rate below 3°C/s to avoid thermal shock to the manganese dioxide cathode layer. Tape-and-reel packaging supports automated pick-and-place.