Bulk decoupling fit and ESR budget
The TPSV477M010R0100: The 2924 case (7.30 x 6.10 mm footprint) is the standard high-capacitance tantalum form factor — the pad layout matches the EIA-7361 metric code. Seated height is 3.75 mm max, so it clears a 4 mm keep-out zone under a mezzanine board.
Temperature range and rework consideration
-55 to 125°C operating range covers the full industrial temperature band and the lower end of automotive under-hood ambient. The molded epoxy case handles the thermal cycling without cracking the element — a known failure mode in dipped tantalums. Surface-mount 2924 with a molded body reflows cleanly with a standard lead-free profile (peak 260°C). The part is not moisture-sensitive per J-STD-020 level 1 — no bake required before rework, which saves time at the bench.