AEC-Q200 qualified bulk decoupling for automotive ECUs
2000-hour endurance at 125°C defines thermal margin
This sets the upper thermal operating limit; for continuous use above 85°C, derating the applied voltage by 20% is standard practice to stay within the endurance window.
D-case 2917 footprint and ESR for power rail design