The SPA11N60CFDXKSA1: That means the TO-220-3 Full Pack needs a heatsink sized for the actual ambient; the full-pack isolation simplifies mounting but raises thermal resistance compared to a standard TO-220.
NRND — planning the last-time buy
Sourcing through independent distribution — where sealed reels and consistent date-codes from factory excess lots are available — is the practical route to fill remaining production runs.
Package and temperature — mounting and environment
The PG-TO220-3-31 (TO-220-3 Full Pack) is a through-hole, fully isolated package — no extra isolation washer needed, but the thermal pad is on the back of the plastic body, so the thermal interface to the heatsink is through the plastic, not a metal tab.