600 V, 6 A NPT IGBT in a surface-mount DPak
It targets hard-switching applications like motor drives, PFC stages, and general-purpose inverters where the 600 V breakdown and 6 A continuous collector current fit the bill. The NPT structure gives it a short-circuit withstand capability and a positive temperature coefficient that simplifies paralleling — useful when you need to spread the load across multiple devices. Gate charge is 14 nC. Switching energy per cycle is 36 µJ on and 28 µJ off under 400 V bus, 2 A, and a 118 Ω gate resistor. The junction temperature range spans -55 to 150 °C, so the part is comfortable in environments that see extreme cold or sustained heat — think outdoor telecom cabinets, engine compartments, or industrial drives near ovens.
The SGD02N60 comes in a TO-252-3 (DPak) surface-mount package, supplier device code PG-TO252-3-11. The DPak footprint is standard for this current and voltage class — three leads plus a tab that carries the collector. The tab is electrically live, so the PCB layout must account for creepage and clearance to adjacent traces.