Infineon Technologies IPS6041STRLPBF — Power Management (PMIC / Gate Driver)

IPS6041STRLPBF High-Side Switch, 2.3 A, 110 mOhm, D2Pak

MPNIPS6041STRLPBF
Obsolete

Infineon IPS6041STRLPBF, high-side power switch, 1 output, N-channel, 2.3 A max, 110 mOhm typ Rds(on), 6 V to 28 V load, TO-263-5 D2Pak, -40°C to 150°C, Cut Tape.

Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

IPS6041STRLPBF specifications
ParameterValue
Input typeNon-Inverting
Output typeN-Channel
TypeGeneral Purpose
MountingSurface Mount
Voltage - load6V ~ 28V
Voltage - supply (Vcc (Vdd))Not Required
Output current2.3A
I/O channels1
InterfaceOn/Off
Operating temperature-40°C~150°C(TJ)
PackageCut Tape (CT)
FeaturesAuto Restart
Rds on110mOhm
CaseTO-263-5, D²Pak (4 Leads + Tab), TO-263BB
Fault protectionCurrent Limiting (Fixed), Open Load Detect, Over Temperature
Output configurationHigh Side
Ratio - Input:Output1:1

Product details

Infineon lists the IPS6041STRLPBF as Obsolete. If you have this on a BOM line, the first question is whether you can source enough for the remaining production run, or whether it is time to qualify a replacement.

Switch parametrics — the numbers that matter

This is a single-channel high-side N-channel power switch in a TO-263-5 D2Pak package. The typical on-resistance is 110 mOhm — that is the conduction loss figure you need for the thermal calculation at your load current. Maximum continuous output is 2.3 A, and the load supply range spans 6 V to 28 V. No separate Vcc supply is needed — the switch is self-powered from the load rail. The input is non-inverting, On/Off interface, with a 1:1 input-to-output ratio. That means a logic high on the input turns the switch on — straightforward drive from a GPIO or a relay driver.

Protection set — what trips and what recovers

Fault protection includes current limiting (fixed), open-load detection, and over-temperature shutdown. The Auto Restart feature means the switch attempts to re-start after a fault condition clears — useful for driving lamps or motors where a momentary overload is expected, but something to account for in the system fault-handling logic.

The D2Pak package with its exposed tab conducts heat to the board copper. A thermal-via pattern under the tab is expected for sustained loads.

Frequently asked questions

What does the Auto Restart feature do on this switch?

Auto Restart means the switch automatically attempts to turn back on after a fault condition — such as over-temperature or over-current — clears. This is typical for driving loads like incandescent lamps or DC motors where inrush current may trip the protection momentarily. The switch will cycle on and off until the fault is removed.