Skip to main content
Infineon Technologies IHW40T60

Infineon IHW40T60 IGBT, 600 V 80 A TrenchStop TO-247

MPNIHW40T60
End of Life

Infineon TrenchStop IGBT, IHW40T60, 600 V Vces, 80 A Ic, 2.05 V Vce(on) typ, 920 µJ switching energy, TO-247-3, -40 to 175 °C junction.

$2.3Ref. price · indicative, final on quote
PackagingTO-247-3
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

IHW40T60 Technical Specifications
ParameterValue
SeriesTrenchStop®
IGBT typeTrench Field Stop
Input typeStandard
Mounting typeThrough Hole
Voltage - collector emitter breakdown600 V
Current - collector (Ic)80 A
Current - collector pulsed120 A
Power - max303 W
Operating temperature-40°C ~ 175°C (TJ)
PackageBulk
Gate charge215 nC
CaseTO-247-3
Test condition400V, 40A, 5.6Ohm, 15V
Switching energy920µJ
Td (on/off) @ 25°C-/186ns
Vce(on) (Max) @ vge, ic2.05V @ 15V, 40A
Reverse recovery time143 ns

Product details

600 V, 80 A TrenchStop IGBT for hard-switched power stages

The IHW40T60: It targets hard-switched inverter and motor-drive stages where conduction and switching losses need balancing.

Conduction and switching loss numbers that size the heatsink

At 400 V, 40 A, 5.6 Ω gate resistor, and 15 V gate drive, typical Vce(on) is 2.05 V. Switching energy is 920 µJ under the same condition. Gate charge totals 215 nC. For a 20 kHz hard-switched stage, the average gate-drive power is about 4.3 mW per IGBT, well within a standard driver IC's capability. The turn-off delay time is 186 ns at 25 °C; the datasheet's typical curves show how that shifts with temperature and collector current.

The part is ROHS3 compliant.

Package and mounting — TO-247-3 through-hole

The PG-TO247-3-1 package is the standard TO-247-3 outline with three through-hole leads. The large copper tab provides the collector connection and the primary thermal path. For a 303 W maximum power dissipation, the tab must be bolted to a heatsink with thermal interface material — the junction-to-case thermal resistance in the datasheet drives the heatsink selection.

Frequently asked questions

What is the gate charge and switching energy of IHW40T60?

Total gate charge is 215 nC. Switching energy is 920 µJ, tested at 400 V, 40 A, 5.6 Ω gate resistor, and 15 V gate drive.