1200 V, 60 A TrenchStop IGBT in TO-247-3
The Infineon IHW30N120R5XKSA1 is a Trench Field Stop IGBT rated for 1200 V collector-emitter breakdown and 60 A continuous collector current, with a 90 A pulsed capability.
Conduction and switching losses
At 30 A collector current with 15 V gate drive, the typical Vce(on) is 1.85 V, which keeps conduction losses manageable for a 60 A rated device. Turn-off switching energy is 1.1 mJ under test conditions of 600 V, 30 A, 10 Ohm gate resistor, 15 V gate drive. Gate charge is 235 nC, a figure that informs the gate driver's peak current capability and switching speed trade-off.
The collector tab is electrically live — account for isolation when mounting to a heatsink. The PG-TO247-3 variant uses the same industry-standard hole pattern and lead spacing as other TO-247-3 devices.