Skip to main content
Infineon Technologies IDP15E60

IDP15E60 Diode, 600V 29.2A, 87ns trr, TO-220-2

MPNIDP15E60
End of Life

Infineon IDP15E60, Standard Diode, 600 V DC Reverse, 29.2 A Average Rectified, 87 ns Reverse Recovery Time, TO-220-2, Through Hole, -40°C to 175°C Junction.

$0.8Ref. price · indicative, final on quote
PackagingTO-220-2
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

IDP15E60 Technical Specifications
ParameterValue
SeriesIDP
Diode typeStandard
Mounting typeThrough Hole
Voltage - DC reverse (Vr)600 V
Voltage - forward (Vf) (Max) @ if2 V @ 15 A
Current - reverse leakage @ vr50 µA @ 600 V
Current - average rectified29.2A
Operating temperature - junction-40°C ~ 175°C
SpeedFast Recovery =< 500ns, > 200mA (Io)
PackageBulk
CaseTO-220-2
Reverse recovery time87 ns

Product details

600 V, 29.2 A, 87 ns trr — what this diode delivers

The Infineon IDP15E60 is a standard recovery diode in a TO-220-2 through-hole package, rated for 600 V DC reverse voltage and 29.2 A average rectified current. Its 87 ns reverse recovery time places it in the fast-recovery class (≤ 500 ns at > 200 mA), making it suitable for continuous-conduction-mode boost PFC stages, flyback snubbers, and output rectification in switch-mode power supplies up to several kilowatts. The 175 °C maximum junction temperature gives thermal headroom for high-ambient environments such as industrial motor drives, welding inverters, and server power supplies.

87 ns trr — switching loss and snubber design

The 87 ns reverse recovery time is the key parameter for switching loss.

Lifecycle and sourcing

The IDP15E60 carries an Active lifecycle status, meaning Infineon continues to manufacture it with no announced end-of-life. It is available through independent distribution and quoted to order against an RFQ.

Frequently asked questions

Does IDP15E60 require a heatsink for 15A?

Yes, at 15 A forward current the forward drop is 2 V, producing 30 W of dissipation. A TO-220-2 package requires a heatsink for continuous operation at that level.

What is the replacement for IDP15E60?

No official replacement has been announced since the part is Active. For a pin-compatible alternative within the same series, consider the IDP12E60 if the lower current rating fits the application.