Coilcraft LPS4018-103MRC 10 µH Shielded Power Inductor

MPNLPS4018-103MRC
Active

Coilcraft LPS4018-103MRC, Drum Core, Shielded, 10 µH, ±20%, 900 mA, 1.1 A Isat, 200 mOhm DCR, AEC-Q200, Surface Mount, Nonstandard 3.90mm x 3.90mm x 1.80mm.

$1.1900Ref. price · indicative, final on quote
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LPS4018-103MRC specifications
ParameterValue
TypeDrum Core
SeriesLPS4018
MountingSurface Mount
Current rating900 mA
Current - saturation1.1A
Frequency - self resonant40MHz
Inductance frequency - test100 kHz
Operating temperature-40°C~125°C
Material - coreFerrite
Size (Dimension)0.154\" L x 0.154\" W (3.90mm x 3.90mm)
Height - seated0.071\" (1.80mm)
PackageStrip
RatingsAEC-Q200
ShieldingShielded
Tolerance±20%
Inductance10 µH
CaseNonstandard
DC resistance200mOhm Max

Product details

10 µH shielded drum core — AEC-Q200 qualified

The Coilcraft LPS4018-103MRC is a 10 µH shielded drum-core power inductor in the LPS4018 series, qualified to AEC-Q200 for automotive-grade reliability. Rated for 900 mA continuous current with a saturation current floor of 1.1 A — the margin above the rated current means the inductance holds up under transient loads without collapsing into the resistive regime. Maximum DC resistance is 200 mOhm, which sets the copper-loss budget for the supply rail.

AEC-Q200 and 125 °C operating ceiling

AEC-Q200 qualification certifies the inductor for automotive stress profiles — temperature cycling, mechanical shock, and bias humidity at Grade 1 levels. The ferrite core and shielded construction contain the magnetic flux, reducing radiated EMI into nearby sensitive traces — a common requirement in automotive ECU layouts and compact DC-DC converter modules.

Self-resonant frequency and test conditions

Self-resonant frequency is 40 MHz — well above typical switching frequencies for point-of-load converters (2-5 MHz), so the inductor behaves as a pure inductive element in the passband. Inductance is measured at 100 kHz, the standard test frequency for power inductors in this value range. Tolerance is ±20%, which is typical for shielded power inductors — the saturation current floor is the tighter constraint for design margin, not the inductance tolerance itself.

Frequently asked questions

How do I get current pricing and availability for LPS4018-103MRC?

Pricing and stock are confirmed at quote time. Submit an RFQ for the LPS4018-103MRC; availability and lead time are provided against your BOM quantity.