Skip to main content
Analog Devices MAX31865AAP+T — DC-DC Power Modules

MAX31865AAP+T RTD-to-Digital Converter, ±0.5°C Accuracy, SPI

MPNMAX31865AAP+T
End of Life

Analog Devices MAX31865AAP+T, RTD-to-Digital Converter, ±0.5°C Max Accuracy, SPI Output, 3V–3.6V Supply, -40°C to 125°C, 20-SSOP Surface Mount Package.

$7.63513Ref. price · indicative, final on quote
Packaging20-SSOP (0.209", 5.30mm Width)
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX31865AAP+T specifications
ParameterValue
Output typeSPI
Sensor typeExternal
MountingSurface Mount
Voltage3V ~ 3.6V
Operating temperature-40°C ~ 125°C
PackageTape & Reel (TR); Cut Tape (CT)
Accuracy±0.5°C(Max)
FunctionTemp Monitoring System (Sensor)
TopologyADC (Sigma Delta), Comparator, Register Bank
Output fanNo
Output alarmNo
Case20-SSOP (0.209\", 5.30mm Width)

Product details

RTD front-end in a single 20-SSOP package

It converts the resistance of an external platinum RTD (Pt100 or Pt1000) directly to a digital reading over an SPI interface, with a guaranteed maximum accuracy of ±0.5°C across the full -40°C to 125°C operating range. This part is designed for industrial temperature sensing applications—motor drives, HVAC controllers, process transmitters, and battery-management systems—where a direct digital link to an MCU or FPGA is needed without external signal conditioning.

The ±0.5°C maximum error includes the ADC, reference, and linearisation. The sigma-delta topology rejects line noise.

SPI interface — direct to the MCU bus

Communication is over a standard SPI bus, which means any microcontroller with a spare SPI port can read the conversion result directly from the on-chip register bank. No I²C address conflicts, no bit-banging a custom protocol. The 3V to 3.6V supply range lets it run from a 3.3V rail common on Cortex-M and FPGA boards. The register bank stores configuration, fault status, and the conversion result, so the host can poll or interrupt on threshold alarms—though this variant does not include a dedicated alarm output pin.

Active production, current-date-code supply

No last-time-buy or end-of-life notices are active.

Frequently asked questions

What is the accuracy of MAX31865AAP+T?

This is a system-level spec that includes the ADC, reference, and linearisation for a Pt100 or Pt1000 RTD.

Does MAX31865AAP+T have an SPI interface?

Yes, the output type is SPI. The part communicates over a standard SPI bus, reading the conversion result from the on-chip register bank.

Is MAX31865AAP+T compatible with Pt1000?

Yes, the MAX31865 is designed for both Pt100 and Pt1000 RTDs. The register bank includes configuration bits to select the RTD type and excitation current. The ±0.5°C accuracy spec holds for either sensor.