Skip to main content
Analog Devices MAX16055BAUB+ — DC-DC Power Modules

MAX16055BAUB+ Multi-Voltage Supervisor, 6-Channel

MPNMAX16055BAUB+
End of Life

Maxim Integrated MAX16055BAUB+, Multi-Voltage Supervisor, 6 Channel, Active Low Reset, Open Drain Output, 140ms Minimum Reset Timeout, 10-TFSOP/10-MSOP, -40°C to +125°C.

$8.49Ref. price · indicative, final on quote
Packaging10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX16055BAUB+ specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold6 Selectable Threshold Combinations
Number of voltages monitored6
Operating temperature-40°C ~ 125°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageTube
Reset timeout140ms Minimum
Case10-TFSOP, 10-MSOP (0.118\", 3.00mm Width)

Product details

Six-rail supervisor in a 10-pin MSOP

It asserts a common active-low reset output (open-drain) whenever any monitored rail falls below its programmed threshold, and holds reset for a minimum of 140 ms after all rails recover — enough time for the system power supplies and oscillators to stabilise before the processor boots. The thresholds are factory-programmed per the ordering option; the BAUB+ suffix corresponds to one of the standard threshold sets listed in the datasheet's ordering table.

The reset output stays asserted for a minimum of 140 ms after all monitored voltages rise above their thresholds. Six monitored channels allow supervision of multiple supply rails in a single IC. The open-drain output can be wired-OR with other reset sources.

The part is housed in a 10-lead TFSOP/MSOP with 0.118-inch body width (3.00 mm) and is a surface-mount device. The 10-uMAX/uSOP package shares the same footprint.

It is fully ROHS3 compliant.

Frequently asked questions

What is the reset timeout of MAX16055BAUB+?

The reset timeout is a minimum of 140 ms. The reset output stays low for at least this duration after all monitored voltages rise above their thresholds.

What are the six selectable threshold combinations for MAX16055BAUB+?

The six selectable threshold combinations are factory-programmed and correspond to the ordering suffix. The BAUB+ suffix selects one specific set of thresholds covering common core, I/O, memory, and auxiliary voltages. The exact voltage levels are listed in the datasheet's ordering table.

Is MAX16055BAUB+ RoHS compliant?

Yes, the MAX16055BAUB+ is ROHS3 compliant.

What is the closest pin-compatible alternative to MAX16055BAUB+?

Maxim offers several multi-voltage supervisors in the same 10-uMAX package family with different threshold combinations and reset timeout options. The MAX16056 through MAX16059 series share the same pinout and package, differing only in the factory-set thresholds and reset timeout values. Check the ordering table in the datasheet to select the variant that matches your rail voltages.