DS3502U+T&R

Analog Devices

Analog Devices DS3502U+T&R digital potentiometer, 10kΩ, 128 taps, linear taper, I²C, non-volatile, 10-uMAX/uSOP, -40°C to 100°C.

Analog Devices DS3502U+T&R
Download datasheet (PDF)
[IN STOCK] In Stock: 38 pcs
$5.77/ pc

Volume pricing

Buy Now

MOQ 1 · Tape & Reel (TR); Cut Tape (CT) · RoHS · EIA-481 · DAP/DDP · T/T

Technical specifications

DS3502U+T&R specifications
Parameter / AttributeSpecification / Value
Memory typeNon-Volatile
MountingSurface Mount
Supply voltage2.5V ~ 5.5V, 4.5V ~ 15.5V
InterfaceI²C
Operating temperature-40°C ~ 100°C
TaperLinear
PackageTape & Reel (TR); Cut Tape (CT)
FeaturesSelectable Address
Tolerance±20%
ConfigurationPotentiometer
Number of taps128
Case10-TFSOP, 10-MSOP (0.118\", 3.00mm Width)
Resistance10k
Number of circuits1
Temperature coefficient±4ppm/°C
Resistance - wiper (Ohms)5000

Technical details

Linear taper and tap resolution for calibration loops

The DS3502U+T&R uses a linear taper, meaning each of the 128 taps increments the wiper-to-B resistance by an equal step of about 78 Ω across the 10 kΩ end-to-end resistance. The non-volatile memory stores the wiper position at power-down and restores it on the next power-up, so the calibration value survives a cycle without host intervention. Resistance tolerance is ±20% — typical for digital potentiometers — but the ratiometric tap-to-tap matching is far tighter, so the divider ratio accuracy is what matters in most applications.

I²C bus integration and address flexibility

Communication runs over the I²C interface, and the selectable address feature lets up to eight DS3502 devices share the same two-wire bus without address collision. This is useful in multi-channel systems where each channel's offset or gain needs independent trimming. This split-rail architecture means the wiper voltage can swing well above the logic supply, suiting it for applications like programmable current sources or high-side voltage dividers where the signal common is not at ground.

Temperature stability and industrial operating range

The temperature coefficient is ±4 ppm/°C typical — over a 100°C swing the resistance drifts by only about 0.04%, which is negligible for most trimming and calibration roles. The operating temperature range spans -40°C to 100°C, covering industrial and outdoor equipment without needing a commercial-grade part. Package is the 10-uMAX/uSOP, a 3 mm-wide, 0.118-inch pitch MSOP-style footprint. The narrow body saves board area in dense mixed-signal layouts, but the 0.5 mm lead pitch requires careful solder-paste stencil design for reliable reflow.

Lifecycle and compliance posture

Analog Devices lists the DS3502U+T&R as Active with ROHS3 compliance. No pin-compatible second source is documented in the available records.