Dropout voltage and input range — headroom matters at 1.2 V out
Maximum dropout is 0.25 V at 250 mA. Input maximum is 5.5 V. Operating temperature range is -40°C to 125°C.
Package and footprint — 4-X2SON (1x1 mm)
The 4-X2SON measures 1x1 mm with an exposed pad for thermal transfer. The exposed pad must be soldered to a PCB copper plane to reach the rated 250 mA without thermal shutdown.
Lifecycle and sourcing — active, no LTB risk
Listed as Active with ROHS3 compliance. No end-of-life notice or last-time-buy schedule has been issued.