Skip to main content
Taiwan Semiconductor Corporation 1.5SMC68A M6G — Circuit Protection

1.5SMC68A M6G TVS Diode, 1500W Peak, DO-214AB

MPN1.5SMC68A M6G
Active

Taiwan Semiconductor 1.5SMC68A M6G unidirectional Zener TVS diode, 58.1V standoff, 92V clamping @ 17A peak pulse, 1500W peak pulse power, DO-214AB SMC surface mount, -55°C to 150°C junction.

Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1.5SMC68A M6G specifications
ParameterValue
TypeZener
Series1.5SMC
MountingSurface Mount
Voltage - breakdown64.6V
Voltage - clamping (Max) @ ipp92V
Voltage - reverse standoff58.1V
Current - peak pulse (10/1000μs)17A
Power - peak pulse1500W (1.5kW)
Power line protectionNo
Operating temperature-55°C~150°C(TJ)
PackageTape & Reel (TR)
ApplicationsGeneral Purpose
CaseDO-214AB, SMC
Unidirectional channels1

Product details

The 1.5SMC68A M6G: The 1500W peak pulse rating (10/1000µs waveform) is the spec that decides whether this part clears the transient energy budget in your power rail — a lightning-induction event or inductive kick on a supply line dumps energy into the clamping element, and that 1500W ceiling tells you how much the TVS can absorb without failing. The 17A peak pulse current confirms the clamping path can be drawn through the device without the clamping voltage climbing above the 92V ceiling that downstream circuitry must survive. The standoff voltage of 58.1V typ sits comfortably above the normal operating rail — the TVS stays non-conductive during normal operation and turns on only when the transient pushes the line above the 64.6V minimum breakdown threshold. That ~6V gap between nominal standoff and breakdown is tight enough to keep protection responsive without nuisance triggering on legitimate supply variations.

Voltage stack for circuit protection design

The 92V maximum clamping voltage at 17A peak pulse is the design ceiling for whatever is downstream — the protected circuit must tolerate 92V for the pulse duration without damage. In practice the clamping voltage tracks the Ipp curve; at lower transient currents the clamp sits closer to the 64.6V breakdown minimum, giving protected devices more margin. This is why the peak pulse power and the peak pulse current are both on the datasheet — the designer checks both against the expected transient waveform and the downstream breakdown-withstand rating. The unidirectional channel means protection is on one polarity only — the standoff and breakdown ratings apply in the reverse direction, which is the normal polarised supply case. For bidirectional or AC rails a bidirectional TVS would be required; the single unidirectional channel here marks this as a DC rail clamp.

DO-214AB SMC package for surface-mount assembly

The DO-214AB (SMC) package is the common large-MELF footprint for TVS diodes handling 1500W and above — the generous die-attach pad under the body gives better thermal transfer to the board plane than a smaller SMA or SMB. Junction temperature is rated to 150°C with a -55°C low end, covering automotive under-hood and industrial environments without derating concerns at the lower end of the range. The Tape & Reel packaging is standard for SMT assembly flow.

The 1.5SMC68A M6G carries Active lifecycle status from Taiwan Semiconductor Corporation. The part is quoted to order through independent distribution — availability and lead time confirmed against the BOM quantity at RFQ. The base product number 1.5SMC68 groups with the full series, so same-family sourcing is worth exploring if the exact MPN is constrained by a single-source BOM.

Frequently asked questions

What does the 58.1V standoff voltage and 92V clamping rating mean for my supply rail?

The 58.1V standoff is the maximum reverse voltage the TVS holds off during normal operation — the supply rail should sit below this so the device stays non-conductive. When a transient exceeds the 64.6V minimum breakdown, the TVS clamps at up to 92V, so the downstream circuitry must withstand 92V for the pulse duration. Those two numbers define the protection window for the design.

What is the 1.5SMC68A M6G used for?

The 58.1V standoff makes it suited for 48V nominal supply rails with adequate headroom. The 1500W peak pulse rating handles the energy from inductive load switching and lightning-induction transients in industrial and telecom power distribution.