Skip to main content
Taiwan Semiconductor Corporation 1.5KE56A R0G — Circuit Protection

1.5KE56A R0G TVS Diode, 1500W, 77V Clamp, DO-201

MPN1.5KE56A R0G
Active

Taiwan Semiconductor 1.5KE series Zener TVS diode, 1.5KE56A R0G, 1500W peak pulse power, 77V clamping, 20A Ipp, DO-201AA axial, through hole.

Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1.5KE56A R0G specifications
ParameterValue
TypeZener
Series1.5KE
MountingThrough Hole
Voltage - breakdown53.2V
Voltage - clamping (Max) @ ipp77V
Voltage - reverse standoff47.8V
Current - peak pulse (10/1000μs)20A
Power - peak pulse1500W (1.5kW)
Power line protectionNo
Operating temperature-55°C~175°C(TJ)
PackageTape & Reel (TR)
ApplicationsGeneral Purpose
CaseDO-201AA, DO-27, Axial
Unidirectional channels1

Product details

1500 W axial TVS for 48 V rail clamping

The 1.5KE56A R0G: With a 47.8 V reverse standoff voltage and a minimum breakdown of 53.2 V, it clamps transients at 77 V maximum while conducting 20 A peak pulse current. The DO-201AA axial-lead package (DO-27 footprint) is a through-hole form factor that survives rework with a standard soldering iron — no hot-air station needed for a field swap.

Clamping voltage and pulse current — what they mean on a 48 V bus

The 77 V clamping voltage at 20 A means a 48 V nominal bus (battery or telecom) sees transients held to under 80 V — well within the typical 100 V rating of downstream DC-DC converters and POL regulators. The 1500 W peak pulse rating at 10/1000 µs is the standard telecom surge waveform; for shorter pulses (8/20 µs) the device handles significantly higher peak current, but the 20 A figure at the longer waveform is the conservative design-in number.

Active production — sourcing posture

No official second-source or pin-compatible cross-reference is listed — the DO-201 footprint is standard across the 1.5KE family, but the breakdown voltage bin (53.2 V min) is specific to the 56A variant.

Frequently asked questions

What is the 1.5KE56A R0G used for?

The 1500 W pulse rating handles surge events without the part failing short.