1.5KE400CA A0G — 1500W bidirectional TVS in the DO-201 axial package
The 342V reverse standoff voltage means the rail it protects should stay below that level in normal operation.
Minimum breakdown voltage is 380V; the device starts conducting in avalanche at that threshold. The 548V clamp voltage is the maximum the load sees during the transient — a downstream 600V-rated MOSFET or capacitor has margin. The DO-201AA axial package (DO-27 equivalent) handles the 1500W pulse through its lead-frame and junction size.