Skip to main content
Taiwan Semiconductor Corporation 1.5KE24A A0G — Circuit Protection

1.5KE24A A0G TVS Diode, 1500W, 20.5V Standoff, DO-201

MPN1.5KE24A A0G
Active

Taiwan Semiconductor Corporation 1.5KE series Zener TVS diode, 1.5KE24A A0G, 1500W peak pulse power, 20.5V reverse standoff, 33.2V clamping, 47A peak pulse current, DO-201AA/DO-27 axial package, through-hole.

Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1.5KE24A A0G specifications
ParameterValue
TypeZener
Series1.5KE
MountingThrough Hole
Voltage - breakdown22.8V
Voltage - clamping (Max) @ ipp33.2V
Voltage - reverse standoff20.5V
Current - peak pulse (10/1000μs)47A
Power - peak pulse1500W (1.5kW)
Power line protectionNo
Operating temperature-55°C ~ 175°C (TJ)
PackageTape & Box (TB)
ApplicationsGeneral Purpose
CaseDO-201AA, DO-27, Axial
Unidirectional channels1

Product details

Transient protection for 24V DC rails

The 1.5KE24A A0G: With a 20.5V reverse standoff voltage, it sits below the 24V rail to remain transparent during normal operation, while the 22.8V minimum breakdown and 33.2V maximum clamping at 47A define the protection window for the downstream circuitry.

Package and temperature range for industrial use

Housed in a DO-201AA / DO-27 axial leaded package, the through-hole mounting suits point-to-point wiring or PCB layouts where a robust mechanical anchor is preferred over surface-mount. Note that power line protection is not listed — this device is intended for secondary DC rail or signal line clamping, not for direct mains AC protection.

Active lifecycle with no obsolescence risk

As a general-purpose Zener TVS diode, it is a standard catalog part with broad availability through distribution channels — no single-source risk or allocation concerns typical of niche or custom protection devices.

Frequently asked questions

Is 1.5KE24A A0G suitable for protecting a 24V DC power supply?

Yes, the 20.5V reverse standoff voltage is appropriate for a nominal 24V DC rail, allowing normal operation without leakage. The 33.2V clamping limit protects downstream components from overvoltage during surge events up to 1500W peak pulse power.