Clamping parameters and pulse handling
The 1.5KE170A R0G: The reverse standoff voltage is 145 V, meaning the device stays transparent on a nominal 120-130 V rail and only conducts when the line exceeds the 162 V minimum breakdown threshold.
Sourcing and lifecycle posture
Marked as Active on the manufacturer's lifecycle record — no NRND or EOL flag on this order code.