170 V, 10 A dual Schottky in a fully isolated tab
Forward voltage and leakage at temperature
At 10 A forward current the maximum Vf is 900 mV — the actual drop at lower currents or elevated junction temperature will be lower, but the 175°C maximum junction rating means the leakage at 170 V (15 µA at 25°C) rises sharply above 100°C. Budget the leakage term in the thermal calculation for continuous high-line operation.
TO-220 Full Pack — no insulating washer needed