NRND — plan the last-time buy or alternate now
That means STMicroelectronics is no longer qualifying this part for new designs, though existing production builds can still be supplied through the remaining lifecycle window.
600 V, 23 A, 150 mΩ — the switching-stage fit
The 600 V drain-to-source breakdown voltage and 23 A continuous drain current (rated at case temperature 25 °C) place it in the class of devices used in offline switch-mode power supplies, PFC stages, and motor-drive inverters where the DC bus sits at 400 V or below.
TO-220FP — isolated package, no mounting hardware
For a design pulling 23 A continuous, the junction-to-case thermal path will be the limiting factor; the heatsink selection needs to keep the junction temperature at or below the 150 °C absolute maximum.
Gate drive and switching parameters
At 100 kHz and 10 V gate drive, that works out to about 62.5 mW of gate-drive loss.