Skip to main content
NXP Semiconductors NVT2010PW,118 — Discrete Semiconductors

NXP NVT2010PW,118 Bidirectional Voltage Level Translator

MPNNVT2010PW,118
End of Life

NXP NVT2010PW,118 bidirectional voltage level translator, 10 channels, auto-direction sensing, open-drain/push-pull outputs, VCCA 1–3.6V, VCCB 1.8–5.5V, -40 to 85°C, 24-TSSOP.

$1.34Ref. price · indicative, final on quote
Packaging24-TSSOP (0.173", 4.40mm Width)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

NVT2010PW,118 Technical Specifications
ParameterValue
Output typeOpen Drain, Push-Pull
Channel typeBidirectional
Mounting typeSurface Mount
Translator typeVoltage Level
Voltage - VCCA1 V ~ 3.6 V
Voltage - VCCB1.8 V ~ 5.5 V
Operating temperature-40°C ~ 85°C (TA)
PackageTape & Reel (TR); Cut Tape (CT)
FeaturesAuto-Direction Sensing
Case24-TSSOP (0.173\", 4.40mm Width)
Number of circuits1
Channels per circuit10

Product details

Voltage ranges and channel count — fit for mixed-voltage buses

VCCA accepts 1 V to 3.6 V; VCCB accepts 1.8 V to 5.5 V.

Auto-direction sensing — one less GPIO to manage

The auto-direction sensing feature monitors each channel's voltage transition and switches the pass-gate direction accordingly. No DIR pin means one fewer GPIO on the host controller and simpler PCB routing. The translator handles open-drain outputs (for I²C, SMBus) and push-pull outputs (for SPI, UART, general-purpose GPIO) without external pull-up resistors on the push-pull lines — though open-drain lines still need pull-ups to the respective supply rail.

Lifecycle and compliance — active, ROHS3, no LTB risk

ROHS3 compliant. No last-time-buy notice or end-of-life window is on record.

Frequently asked questions

Does NVT2010PW support open-drain and push-pull outputs?

Yes, the output type supports both open-drain and push-pull configurations, selected per application.

Does NVT2010PW require external pull-up resistors?

For open-drain operation, external pull-up resistors to the respective supply rail are needed. For push-pull operation, no pull-ups are required.

Is NVT2010PW a direct replacement for NVT2006?

The NVT2010PW offers 10 channels versus the NVT2006's 6 channels, both with auto-direction sensing in similar supply ranges. Pin compatibility depends on the package; verify the pinout before substituting.