Skip to main content
Littelfuse Inc. 1206SFS450F/32-2 — Circuit Protection

Littelfuse 1206SFS450F/32-2 SFS Fuse, 4.5 A, 32 VDC

MPN1206SFS450F/32-2
Obsolete

Littelfuse SFS series, board mount slow-blow fuse, 1206 (3216 Metric) package, 4.5 A, 32 VDC, 50 A breaking capacity, UL recognized, Tape & Reel.

$0.9300Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1206SFS450F/32-2 specifications
ParameterValue
SeriesSFS
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating4.5 A
Response timeSlow Blow
Operating temperature-55°C ~ 125°C
Size (Dimension)0.126\" L x 0.063\" W x 0.038\" H (3.20mm x 1.60mm x 0.97mm)
Approval agencyUL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t3.6
Case1206 (3216 Metric)
DC cold resistance0.02 Ohms

Product details

4.5 A slow-blow in a 1206 footprint

The Littelfuse 1206SFS450F/32-2 is a 4.5 A surface-mount slow-blow fuse from the SFS series, rated for 32 VDC with a 50 A interrupting capacity at that voltage. The slow-blow characteristic means it tolerates brief inrush current pulses without nuisance opening — the 3.6 A²s melting I²t gives a quantitative handle on how much energy the element absorbs before clearing.

What the ratings mean for the board

Rated 4.5 A continuous at 32 VDC — the 50 A breaking capacity means it safely interrupts a fault current up to that level without rupturing the 1206 ceramic body, which is the key safety spec for a secondary-side DC rail fuse.

Obsolete — sourcing through surplus channels

The UL recognition carries over to any genuine Littelfuse stock, so the safety certification holds for the sourced part.

Frequently asked questions

How can I order the 1206SFS450F/32-2 or check stock?

Current pricing and available quantities are confirmed at quote time — submit an RFQ for your BOM quantity.

What does the 3.6 A²s melting I²t mean for my circuit?

The 3.6 A²s I²t is the energy needed to melt the fuse element. A slow-blow fuse with this I²t can pass a capacitor charging inrush or a motor start surge that lasts a few milliseconds without opening — the energy in the pulse stays below the fuse's thermal clearing threshold.