Skip to main content
Littelfuse Inc. 1206SFF700F/32-2 — Circuit Protection

Littelfuse 1206SFF700F/32-2 7A Fast Blow Fuse, 24V

MPN1206SFF700F/32-2
Obsolete

Littelfuse Inc. 1206SFF series, Board Mount (Cartridge Style Excluded) fast-blow fuse, 1206SFF700F/32-2, 7 A, 24 V DC, 45 A breaking capacity, surface mount, 1206 (3216 Metric) package, Tape & Reel (TR) Cut Tape (CT).

$1.1700Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1206SFF700F/32-2 specifications
ParameterValue
Series1206SFF
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC24 V
Breaking capacity @ rated voltage45A
Current rating7 A
Response timeFast Blow
Operating temperature-55°C ~ 125°C
Size (Dimension)0.126\" L x 0.063\" W x 0.043\" H (3.20mm x 1.60mm x 1.10mm)
Approval agencyUL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t1.75
Case1206 (3216 Metric)
DC cold resistance0.011 Ohms

Product details

7 A fast-blow fuse, 24 V DC rail, 45 A interrupting rating

The Littelfuse 1206SFF700F/32-2 is a 7 A fast-blow surface-mount fuse from the 1206SFF series, rated for 24 V DC with a breaking capacity of 45 A at rated voltage. The 45 A interrupting rating means this fuse can safely clear a fault current up to that level without rupturing or sustaining an arc — critical for protecting downstream traces and components in a 24 V power distribution bus.

Melting I²t and coordination for secondary-side protection

With a melting I²t of 1.75, this fuse coordinates with downstream semiconductor ratings — the energy let-through stays below the surge capability of typical Schottky rectifiers and DC-DC converter input stages on a 24 V rail. The fast-blow response time suits applications where the load inrush is minimal and the fuse must open quickly on a hard short — secondary-side protection in DC-powered equipment, instrumentation, or battery-management circuits.

Obsolete — sourcing through independent channels

Littelfuse has marked the 1206SFF700F/32-2 as obsolete. For existing BOM lines, this part is available through independent surplus and broker channels.

UL recognized — compliance basis for equipment certification

The fuse carries UL recognition, which certifies that the construction and performance meet UL 248-14 for supplemental fuses — a prerequisite for UL 60950 or UL 62368 end-equipment safety certification. Operating temperature range spans -55°C to 125°C, covering industrial and automotive under-hood ambient conditions without derating the current rating at the upper end.

1206 footprint — board layout and reflow profile

The DC cold resistance of 0.011 ohms keeps voltage drop below 80 mV at rated current — negligible in a 24 V rail.

Frequently asked questions

What is the breaking capacity of the 1206SFF700F/32-2 at 24 V DC?

The fuse is rated for 45 A breaking capacity at 24 V DC. This is the maximum fault current it can safely interrupt at the rated voltage.