Skip to main content
Littelfuse Inc. 1206SFF175F/63-2 — Circuit Protection

Littelfuse 1206SFF175F/63-2 SFF Fuse, 1.75 A, 63 VDC

MPN1206SFF175F/63-2
Obsolete

Littelfuse SFF series, board mount fast-blow fuse, 1206 (3216 metric), 1.75 A, 63 VDC, 50 A breaking capacity, 0.1 Ohms DC cold resistance, UL recognized.

$0.9400Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1206SFF175F/63-2 specifications
ParameterValue
SeriesSFF
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC63 V
Breaking capacity @ rated voltage50A
Current rating1.75 A
Response timeFast Blow
Operating temperature-55°C ~ 125°C
Size (Dimension)0.126\" L x 0.063\" W x 0.043\" H (3.20mm x 1.60mm x 1.10mm)
Approval agencyUL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t0.045
Case1206 (3216 Metric)
DC cold resistance0.1 Ohms

Product details

Obsolete — sourcing the 1206SFF175F/63-2 on the spot market

Littelfuse has marked the 1206SFF175F/63-2 as obsolete. No official successor order code is listed, so the only channel is independent surplus and excess inventory. This is a last-time-buy situation: once the remaining stock in the distribution pipeline and on broker shelves is gone, the part is gone. Any BOM that still carries this line item needs a confirmed source now.

1.75 A fast-blow in a 1206 footprint — what the ratings mean

Rated 1.75 A continuous at 63 VDC, this is a fast-blow fuse — it opens quickly on overcurrent, not on sustained low-level overloads. The 50 A breaking capacity at the rated voltage means it can safely interrupt a fault current up to that level without rupturing the ceramic body. The 0.045 melting I²t is the energy needed to clear the element. For a 1.75 A rail, this is a low I²t value — the fuse responds fast to short-circuit pulses, which matters when protecting a sensitive load that cannot ride through a long arc. DC cold resistance is 0.1 Ohms. At 1.75 A, the resistive voltage drop is 175 mV — negligible for a 63 V rail but worth checking if the load is a low-voltage sensor that sees the fuse drop as a supply sag.

1206 footprint and surface-mount integration

Standard 1206 (3216 metric) chip footprint, surface-mount. Tape & Reel and Cut Tape packaging — the reel quantity is standard for the SFF series. The UL recognition covers the fuse's safety performance in the end equipment.

Frequently asked questions

What is the closest alternative to 1206SFF175F/63-2 in the SFF family?

No pin-compatible or functional equivalent is listed as an official successor. The SFF series includes other ratings in the same 1206 footprint, but a different current or voltage rating changes the protection profile — a BOM substitution requires verifying the new fuse's I²t and breaking capacity against the circuit requirements.