Littelfuse 0603SFF200F/32-2 SFF 2A 32V Fast-Blow Fuse

MPN0603SFF200F/32-2
Obsolete

Littelfuse Inc. SFF series, Board Mount (Cartridge Style Excluded) fast-blow fuse, 0603 (1608 Metric), 2 A, 32 V DC, 35 A breaking capacity, UL recognized, Tape & Reel (TR); Cut Tape (CT).

$1.6900Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

0603SFF200F/32-2 specifications
ParameterValue
SeriesSFF
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage35A
Current rating2 A
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.063\" L x 0.031\" W x 0.031\" H (1.60mm x 0.80mm x 0.80mm)
Approval agencyUL
PackageTape & Reel (TR); Cut Tape (CT)
Melting i2t0.06
Case0603 (1608 Metric)
DC cold resistance0.052 Ohms

Product details

Obsolete — sourcing the 0603SFF200F/32-2 for BOM fill

The Littelfuse 0603SFF200F/32-2 is officially listed as obsolete. This means the manufacturer no longer produces it, and the only supply channel is independent surplus or broker inventory.

2 A fast-blow in 0603 — what the ratings mean for circuit protection

Rated 2 A at 32 V DC, this is a fast-blow chip fuse in the 0603 (1608 Metric) surface-mount package. The 35 A breaking capacity at rated voltage means it can safely interrupt a fault current up to that level without rupturing the package. The melting I²t of 0.06 A²s indicates how much energy the fuse absorbs before opening — useful for sizing the fuse against inrush current from a capacitive load or a DC-DC converter input. A downstream capacitor bank with a higher I²t surge will nuisance-blow this part. DC cold resistance is 0.052 Ohms, which at 2 A produces a voltage drop of roughly 0.1 V — negligible in a 32 V rail but a factor in low-voltage circuits where every millivolt of headroom matters.

UL recognition and temperature range for deployment

UL recognized — the approval agency listed on the spec — confirms the fuse meets UL 248-14 for branch-circuit protection, which is the standard specifiers look for in North American panel and PCB designs. The SFF series is board-mount (cartridge style excluded), meaning it solders directly to the PCB without a holder.

Sourcing an obsolete 0603 SMD fuse against an RFQ

Because the 0603SFF200F/32-2 is obsolete, availability is limited to surplus and broker channels. Each lot is confirmed at quote time — no standing stock is held. No pin-compatible drop-in replacement from Littelfuse is documented. A cross-reference search against the 2 A, 32 V, fast-blow, 0603 footprint is the practical next step for a BOM revision.

Frequently asked questions

What is the closest alternative to the 0603SFF200F/32-2?

A functional replacement would need to match the 2 A rating, 32 V DC, fast-blow characteristic, and 0603 (1608 Metric) footprint.